Home / Control Panels / AHU Control Panel
AHU Control Panel

The fan doesn't need to run flat out all day

An air handling unit spends most of its life needing far less air than it was sized for. A proper AHU control panel with VFD drives holds the duct pressure or the room condition you actually asked for, and lets the fan slow down the rest of the time — which is where almost all the energy saving in an HVAC system hides.

AHU · VFD Speed Control
RUNNING
AIR HANDLING UNIT FILTER DAMPER DP VFD OUTPUT 50.0 34.6 Hz SETPOINT HELD ✓ SENSE → COMPARE → ADJUST SPEED → HOLD SETPOINT
DriveVFD, closed loop
SensingTemp + DP
InterfaceBMS ready
The short version

What an AHU control panel is actually controlling

An AHU control panel — air handling unit panel — runs the fan, the dampers, the chilled or hot water valve and the safety interlocks for an air handling unit. On paper that sounds like a starter with a few contactors. In practice, the difference between a cheap AHU panel and a properly engineered one shows up on the electricity bill every month for the next fifteen years.

Here is why. Fan power follows roughly the cube of fan speed. Slow a fan to 80% and it draws close to half the power. Almost every AHU is sized for a peak condition that occurs on a handful of days a year, and then runs at that same peak speed all the time because a direct-on-line starter has no other setting. A VFD-driven AHU panel closing the loop on duct static pressure or return air temperature simply lets the fan slow down whenever the building is not asking for full air.

The panel is not the expensive part of an AHU. It is the part that decides what the expensive parts cost you to run — which is a strange thing to save money on.

What we build into an AHU panel

Where these panels go

Pharmaceutical clean rooms and HVAC plant rooms, hospitals and laboratories, food and beverage processing, commercial buildings, hotels and malls, IT and data centre precision cooling, textile and paint shop ventilation, and institutional buildings. We have built AHU panels with YASKAWA VFD drives for institutional HVAC projects including work delivered to IIT Jodhpur — multiple panels, GA drawings approved before manufacturing, and the control schematic supplied with the panel.

Related panels we build

An AHU rarely sits alone. The same plant room usually needs a VFD pump control panel for the chilled water pumps, an APFC panel to fix the power factor that all those motors ruin, an MCC panel for the plant room as a whole, and a fire fighting panel whose trip signal the AHU must obey. Built together, they share one drawing set and one wiring standard.

Control & data

Control, sensing and BMS integration

Every AHU panel is designed, wired, ferruled and load tested in our own Faridabad workshop, and supplied with the GA drawing and control schematic your consultant will ask for.

VFD

Tuned, not just installed

Drive parameters set for the fan and the loop tuned on site. A VFD at default settings hunts, trips and wastes the saving you bought it for.

LOOP

Closed loop on the real variable

Duct static pressure, return air temperature or room condition — whichever your design actually calls for, with the sensor scaled correctly.

FILTER

DP alarm across the filter bank

Filters changed when they are actually blocked, not on a calendar nobody follows. A blocked filter costs more in fan power than the filter costs.

BYPASS

Auto / manual / bypass

If the drive fails, the fan still runs direct-on-line. A hospital does not stop ventilating while a spare is arranged.

TRIP

Fire trip obeyed, always

Hard-wired fire trip input from the fire alarm panel, plus airflow proving and low-limit protection.

BMS

Talks to the building

Modbus RTU or TCP and BACnet where specified, with the point list agreed at drawing stage rather than argued at commissioning.

On the shop floor

Machines we have built

Photographs from our Faridabad workshop and from customer installations.

ahu-control-panel.jpgComplete AHU panel, front
ahu-panel-internal.jpgInternal wiring and ferruling
ahu-panel-vfd.jpgVFD drive mounted
ahu-panel-hmi.jpgHMI setpoint screen
ahu-panel-ga-drawing.jpgGA drawing supplied
ahu-panel-installed.jpgPanel installed in plant room
Specification

What gets fixed before we cut steel

HVAC panels are usually built to a consultant specification, so we work from the schedule and the schematic and confirm every point in writing.

ParameterWhat it coversFixed at
Fan motor ratingkW, voltage and starting method for each fanEnquiry
Control strategyConstant volume, VAV, DP control or temperature controlEnquiry
VFD selectionMake and rating, with bypass arrangement if requiredDrawing approval
SensorsTemperature, humidity, duct DP, filter DP — type and rangeDrawing approval
Dampers and valvesActuator type, modulating or two-position, fail positionDrawing approval
InterlocksFire trip, airflow proving, low limit, door interlockGA approval
BMS protocolModbus RTU or TCP, BACnet, and the agreed point listGA approval
EnclosureIP rating, material, mounting and cable entryGA approval
DocumentationGA drawing, control schematic, cable schedule, test reportAlways

Why the drawing comes before the panel

On HVAC projects the panel usually has to satisfy a consultant, a contractor and a facilities team who will inherit it. So we issue the GA drawing and control schematic first, get them approved, and build to the approved set — which is what stops the argument at handover about whether the fire trip was supposed to be hard-wired or through the BMS.

Every panel leaves with the approved drawings, the cable schedule, the VFD parameter list and a load test report. The facilities engineer who opens it in five years gets a panel that matches its drawing.

Questions we get asked

Before you send an enquiry

Do we really need a VFD on an AHU?

If the load varies at all, yes. Fan power follows roughly the cube of speed, so running at 80% speed uses close to half the power. Most AHUs are sized for a peak that happens on a few days a year and then run at that speed permanently. The drive pays for itself out of that gap.

What should the panel control on — pressure or temperature?

Duct static pressure where you have VAV boxes downstream and the system must respond to their demand. Return air or room temperature where the AHU serves a fixed space. Your design decides it, and we wire and scale the sensor to match.

What happens if the VFD fails?

With a bypass arrangement the fan runs direct-on-line while the drive is repaired or replaced. For hospitals, clean rooms and process ventilation we recommend it as standard rather than as an option.

Can the panel talk to our BMS?

Yes — Modbus RTU or TCP, and BACnet where the specification calls for it. We agree the point list at drawing approval stage so commissioning is a connection rather than a negotiation.

Do you supply the GA drawing and control schematic?

Yes, before manufacturing. Approval of the drawing is what we build to, and the approved set is handed over with the panel along with the cable schedule and test report.

Do you build panels for multiple AHUs on one project?

Yes. We have supplied multi-panel institutional HVAC projects with common wiring standards and a single drawing set, including work delivered to IIT Jodhpur with YASKAWA drives.

Do you supply outside Faridabad?

Yes — Delhi NCR, Gurugram, Manesar, Bhiwadi, Ghaziabad, Noida and across India.

Get a quote

Send us the AHU schedule and the control schematic.

Share the drawing or a photo on WhatsApp and we will come back with a method, a cycle time and a price.